How to calculate bagasse consumption in boiler?
How to calculate bagasse consumption in boiler?
Time taken by 0.022686 tons bagasse to drop into the boiler furnace = 12.56 seconds Bagasse flow rate = 6.5025 tons/hr Total bagasse flow rate = 6.5025 x No. of chutes = 26.01 tons/hr The calculation is made for serial No. 1 of Table 1.
How much bagasse is required to produce 1 ton of steam?
(2004) reported that 11 kg of steam is needed to produce 1 kW of electricity and conservative boilers can generate 2.2 ton of steam from one ton of bagasse when 23 bars pressure is applied at 350 °C temperature.
How is boiler ratio calculated?
The boiler evaporation ratio is expressed as follows: Evaporation ratio = quantity of steam generation/quantity of fuel consumed. For example quantity of steam Is 310 ton/hr and fuel is 55 ton/hr then the evaporation ratio is 5.63.
How is boiler TPH calculated?
Fuel Required for 1 TPH Boiler is 351.6 kg/hr. That means by burning 351.6 kg/hr of of Bagasse, you can generate 1000 kg/hr saturated steam at 10.5 kg/cm2(g) pressure.
How is bagasse weight calculated?
Bagasse weighs 0.12 gram per cubic centimeter or 120 kilogram per cubic meter, i.e. density of bagasse is equal to 120 kg/m³. In Imperial or US customary measurement system, the density is equal to 7.49 pound per cubic foot [lb/ft³], or 0.0694 ounce per cubic inch [oz/inch³] .
How is GCV of bagasse calculated?
The GCV of bagasse can be determined by the following equation: GCV [1] = 196.05 x(100-Ww % -WA % )-31.14xWRDs KJ/kg Where :Ww – is the moister content, WA – is the ash content WRDs -is the BRIX . Study shows that 1% reduction of moisture in bagasse increased its calorific value of 196 KJ/kg (47 Kcal/kg).
What is bagasse and its uses?
Bagasse is typically used to produce heat and electricity in sugar mills (cogeneration), but can also be used for paper making, as cattle feed and for manufacturing of disposable food containers. Currently, bagasse is mainly used as a fuel in the sugarcane industry to satisfy its own energy requirements.
What is boiler load index?
Maximum continuous rating is the hourly evaporation that can be maintained for 24 hours. To convert horsepower (hp) into lbs of steam: Multiply hp x 34.5. Example: 100 hp x 34.5 = 3450 lbs of steam per hour. To convert lbs of steam to hp: Divide steam per hour by 34.5. Example: 8625 lbs of steam ÷ 34.5 = 250 hp boiler.
How do you calculate boiler size?
Multiply your square footage by 50 to determine the size of your boiler. For instance, if you house is 1,103 square feet, your heater should be at least 55,150 Btu.
How do I calculate boiler capacity?
Boiler Capacity – Engineering ToolBoxA boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg – hf) m (1).
What is the density of bagasse?
The average values of bulk density measured for Pinus, Eucalyptus, and sugarcane bagasse panels were 0.612, 0.623, and 0.616 g/cm3, respectively.